Eldes EKB3 Manuel d'installation Page 75

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 74
75
75EN
MANUAL ELDES ESIM264 V3.1
Enable Low Battery
notication
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK SMS MESSAGES OK LOW BATTERY EVENT
OK ENABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 061 #
Example: 25061#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
If the household electricity is unstable in the system installation area, the system may temporally lose its power supply and continue op-
erating on the backup battery power. The system supervises the mains power supply and notiies User 1 by SMS text message as well as
indicates system fault condition on the keypad (see 29. INDICATION OF SYSTEM FAULTS) when the mains power is lost. When the mains
power restores, the system will notify User 1 by SMS text message and the keypad will no longer indicate system fault.
By default, system notication by SMS text message regarding mains power supply status is enabled. To disable/enable this notication,
please refer to the following conguration methods.
NOTE: In case of low back-up battery, the system will send the SMS text message to the user and transmit the data message to the moni-
toring station, but will NOT indicate a system fault on the keypad.
Disable mains
power supply loss
notication
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK SMS MESSAGES OK MAIN PWR LOSS EV
OK DISABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 04 0 #
Example: 25040#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Enable mains power
supply restore
notication
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK SMS MESSAGES OK MAIN PWR LOSS EV
OK ENABLE OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 04 1 #
Example: 25041#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Vue de la page 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 167 168

Commentaires sur ces manuels

Pas de commentaire