Eldes EKB3 Manuel d'installation Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
64
64 EN
MANUAL ELDES ESIM264 V3.1
EKB2
Menu path:
On-board PGM output: OK CONFIGURATION OK aaaa OK PGM OUTPUTS OK
ONBOARD OUTPUTS OK OUTPUT 1... 12 OK STATUS OK ENABLED OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 61, PGM output number & parameter status value:
61 oo 1 #
Value: oo – PGM output number, range – [01... 76].
Example: 61031#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Turn OFF PGM output/
Set PGM output start-
up state as OFF
SMS
SMS text message content:
ssss_Coo:OFF or ssss_out-name:OFF
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 76]; out-name
up to 16 characters PGM output name.
Example: 1111_C2:OFF
EKB2
Menu path:
On-board PGM output: OK CONFIGURATION OK aaaa OK PGM OUTPUTS OK
ONBOARD OUTPUTS OK OUTPUT 1... 12 OK STATUS OK DISABLED OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 61, PGM output number & parameter status value:
61 oo 0 #
Value: oo – PGM output number, range – [01... 76].
Example: 61020#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
To instantly turn ON an individual PGM output for a determined time period and automatically turn it OFF when the time period expires,
please refer to the following conguration method.
Turn ON PGM output
for time period
SMS
SMS text message content:
ssss_Coo:ON:hr.mm.sc or ssss_out-name:ON:hr.mn.sc
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 76]; out-name
– up to 16 characters PGM output name; hr – hours, range – [00... 23]; mn – minutes, range
– [00... 59]; sc – seconds, range – [00... 59].
Example: 1111_C4:ON:10.15.35
To instantly turn OFF an individual PGM output for a determined time period and automatically turn it ON when the time period expires,
please refer to the following conguration method.
Turn OFF PGM output
for time period
SMS
SMS text message content:
ssss_Coo:OFF:00.00.sc or ssss_out-name:OFF:hr.mn.sc
Value: ssss – 4-digit SMS password;oo – PGM output number, range – [1... 76]; out-name
– up to 16 characters PGM output name; hr – hours, range – [00... 23]; mn – minutes, range
– [00... 59]; sc – seconds, range – [00... 59].
Example: 1111_Lights:OFF:00.00.23
When the PGM output is turned ON or OFF, the system will send a conrmation by SMS text message to the user phone number that the
SMS text message was sent from.
NOTE FOR EKB2/EKB3/CONFIG TOOL USERS: Only the startup state of the PGM output can be changed using these conguration
methods.
Vue de la page 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 167 168

Commentaires sur ces manuels

Pas de commentaire