108
108 EN
MANUAL ELDES ESIM264 V3.1
31. ELDES WIRED DEVICES
31.1. RS485 Interface
RS485 interface is used for the system to communicate with the following devices:
• EKB2 keypads (up to 4 units).
• EKB3 keypads (up to 4 units).
• EPGM1 modules (1 unit).
The terminals of RS485 interface are Y (yellow wire) and G (green wire), which are clock and data respectively. The devices, connected to
RS485 interface, must be powered from the AUX+ and AUX- terminals.
For more details on RS485 device wiring, please refer to 3.2.7. RS485.
31.1.1. EKB2 - LCD Keypad
EKB2 is an LCD keypad intended for using with ESIM264 alarm system.
Main EKB2 features:
• Alarm system arming and disarming (see 12.3. EKB2 Keypad and User Password).
• Arming and disarming in Stay mode (see 15. STAY MODE).
• System parameter conguration (see 5. CONFIGURATION METHODS).
• PGM output control (see 18.4. Turning PGM Outputs ON and OFF).
• System information display (see 31.1.1.4. Visual and Audio Indications).
• Audio indication by built-in buzzer (see 31.1.1.4. Visual and Audio Indications ).
• Wireless device information display (see 19.2. Wireless Device Information and Signal Status Monitoring).
• Keypad partition switch (see 23.3. Keypad Partition and Keypad Partition Switch).
• Temperature display (see 31.1.1.1.2 Keys Functionality).
• Time display (see 31.1.1.1.2 Keys Functionality).
The system conguration is performed by accessing EKB2 menu and entering the required values. ESIM264 system allows to connect up
to 4 EKB2 keypads.
31.1.1.1. Technical Specications
31.1.1.1.1 Electrical & Mechanical Characteristics
Power Supply 12-14V 150mA max.
Maximum Keypad Connection Cable Length 100 m.
Dimensions 133 x 89 x 19 mm
Humidity
0-90% RH @ 0... +40 °C (non-condensing)
Range of Operating Temperatures 0...+55ºC
Commentaires sur ces manuels