Eldes EKB3 Manuel d'installation Page 157

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 156
157
157EN
MANUAL ELDES ESIM264 V3.1
MOUNTING POINT AMOUNTING POINT B
MOUNTING POINT A
Ensure to screw in properly for supervision of the back side by tamper switch
MOUNTING
POINT B
110 111
3. Remove the plastic tab inserted between one of the battery terminals and battery slot contacts.
The wireless connection loss between EWS3 and ELDES alarm system leads to alarm. The system identies this event as a tamper viola-
tion and sends an alarm by SMS text message and phone call to the user (-s) by default. The SMS
message contains the wireless device model, wireless ID code and tamper number.
112
4. STATUS indicator should start ashing indicating successful data transmission.
5. Close EWS3 enclosure by putting the cover back.
6. Bind the device to the alarm system by sending a corresponding command via SMS text message or using ELDES Conguration Tool
software. Please, refer to the software‘s HELP section or refer to 19.1. Binding, Removing and Replacing Wireless Devices for
more details.
7. The system automatically informs about successful/unsuccessful binding process. If attempt to bind is unsuccessful, try to move
EWS3 closer to alarm system device and bind it again.
ATTENTION: Ensure that EWS3 device is properly xed to the wall and the Mounting Point A portrayed in Fig. No. 110 and Fig. No. 111
is properly screwed in. Otherwise, the tamper switch will NOT supervise the back side of EWS3 enclosure (see also 33.12.3. EWS3
Zone, PGM Output and Tamper).
NOTE: If you are unable to bind the wireless device, please, restore the parameters of the wireless device to default and try again.
See chapter 33.12.5. Restoring Default Parameters for more details.
32.12.3. EWS3 Zone, PGM Output and Tamper
Upon successful EWS3 outdoor siren binding process,the system adds 1 wireless Instant zone and 1 wireless Siren PGM output. The
wireless zone is intended for EWS3 tamper control and ability to assign a partition (-s), while the wireless PGM output is intended for siren
speaker control.
In case of tamper violation, the alarm is caused regardless of system being armed or disarmed. There are 2 ways to detect tamper viola-
tion on EWS3:
• By tamper switch. EWS3 comes equipped with 2 built-in tamper switches intended for enclosure supervision:
one located on the front side of the PCB supervising the front cover in case it is illegally opened (see Fig. No. 107).
the other one located on back of the PCB supervising the back side of the enclosure in case the EWS3 is illegally detached from the
wall (see Fig. No. 107).
Once the enclosure of EWS3 is tampered, the tamper switch will become triggered. This action will be followed by alarm, resulting in
sending an SMS text message and/or phone call to the user. The SMS text message contains the violated tamper number.
• By wireless connection loss. The wireless connection loss between EWS3 and ESIM264 system leads to alarm. The system identies
this event as a tamper violation and sends alarm by SMS text message and phone call to the user (-s) by default. The SMS text message
contains the violated tamper number and a star * character indicating wireless connection loss as a tamper alarm cause.
ATTENTION: The tamper will not operate if the wireless zone is disabled.
Vue de la page 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 167 168

Commentaires sur ces manuels

Pas de commentaire