MANUAL ELDES ESIM264 V3.1
Set delay after last
communication
attempt
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK MS SETTINGS OK DELAY LAST ATTEMPT
OK aaapp OK
Value: aaaa – 4-digit administrator password; aaapp – duration of delay after last attempt,
range – [0... 65535] seconds.
EKB3
Enter parameter 69 & duration of delay after last attempt:
69 aaapp #
Value: aaapp – duration of delay after last attempt, range – [0... 65535] seconds.
Example: 69200#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
NOTE: 0 value disables delay after last communication attempt.
NOTE: The system is fully compatible with Kronos NET/Kronos LT monitoring station software for communication via GPRS network. When
using a dierent monitoring station software, EGR100 middleware is required. EGR100 is freeware and can be downloaded at www.eldes.lt/
en/download
30.2.1. GPRS Network
The system supports data transmission to the monitoring station via IP-based networks by GPRS network. The supported data formats are the
following:
EGR100
Kronos
To set up the system for data transmission via GPRS network, please follow the basic conguration steps:
1. Enable MS Mode parameter (see 30. MONITORING STATION).
2. Set 4-digit Account number (see 30. MONITORING STATION).
3. Set server IP address, which is a public IP address of the machine running EGR100 or, Kronos monitoring station soft ware.
4. Set server port, which is a port of the machine running EGR100 or Kronos monitoring station software.
5. Select TCP or UDP protocol. UDP is highly recommended for EGR100 data format.
6. Select data format: EGR100 ir Kronos.
7. In case EGR100 is selected, set 4-digit Unit ID number. Unit ID number can be identical to Account number.
8. Set up APN, user name and password provided by the GSM operator. De pending on the GSM operator, only APN might be required to set
up.
For detailed step-by-step instructions on how to establish the communication between ESIM264 alarm system and EGR100 middleware, please
refer to the middleware’s HELP le.
Set server IP address
SMS
SMS text message content:
ssss_SETGPRS:IP:add.add.add.add
Value: ssss – 4-digit SMS password; add.add.add.add – server IP address.
Example: 1111_SETGPRS:IP:65.82.119.5
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK GPRS SETTINGS OK SERVER IP OK
add.add.add.add OK
Value: aaaa – 4-digit administartor password; add.add.add.add – server IP address.
EKB3
Enter parameter 40 & server IP address:
40 add add add add #
Value: add add add add – server IP address.
Example: 40065082119005#