31.1.2.1.5 Keypad Address
Pins 3 and 2 located on the back side of the keypad are intended to set keypad address. The keypad address is set by putting the jumper (-s)
on the pins. ESIM264 system allows to connect up to 4 EKB3 keypads - each set under dierent address. Jumper combinations for dierent
keypad address conguration are indicated in the table below.
Address Conguration
Jumper position Address
3 2
1
Keypad 1
3 2
1
Keypad 2
3 2
1
Keypad 3
3 2
1
Keypad 4
NOTE: Pins 1 are inactive.
The address of each connected keypad is also indicated in ELDES Conguration Tool software.
31.1.2.2. Installation
1. Detach keypad holder from EKB3 keypad . Keypad holder detach points are marked with arrows (see Fig. No. 45).