56
56 EN
MANUAL ELDES ESIM264 V3.1
Enable zone
SMS
SMS text message content:
ssss_Znn:ON
Value: ssss – 4-digit SMS password; nn – zone number, range – [1... 44].
Example: 1111_Z6:ON
EKB2
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → STATUS → OK → ENABLE → OK
Wireless zone: OK → CONFIGURATION → STATUS → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → STATUS → OK → DISABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD ZONES
→ OK → KEYPAD 1... 4 ZONE → OK → STATUS → DISABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →
EPGM1 ZONE 1... 16 → OK → STATUS → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 52, zone number & parameter status value:
52 nn 1 #
Value: nn – zone number, range – [01... 44].
Example: 52151#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
15. STAY MODE
Stay mode allows the user to arm and disarm the alarm system without leaving the secured area. If the zones with Stay attribute enabled
are violated when the system is Stay armed, no alarm will be caused. Typically, this feature is used when arming the system at home before
going to bed.
The system can be Stay armed under the following conditions:
• If a zone with Stay attribute enabled is NOT violated during exit delay, the system will arm in Stay mode. When arming the system in
Stay mode under this condition, one of the available arming methods must be used that provide exit delay. For more details on these
methods, please refer to 13. EXIT AND ENTRY DELAY.
• The system will instantly arm in Stay mode when using one of the following methods.
Arm the system in
Stay mode
EKB2
Menu path:
P2 → uuuu → OK
Value: uuuu – 4-digit user password.
EKB3
Press the [STAY] key & enter user password:
STAY uuuu
Value: uuuu – 4-digit user password.
Example: STAY1111
When the system is successfully armed in Stay mode, EKB2 keypad will display STAY message in the home screen view.
ATTENTION: System arming in Stay mode by the keypad must be carried out without Conguration mode being activated.
NOTE: The system can be armed in Stay mode, only if there is at least one zone with Stay attribute enabled.
NOTE: Stay mode is not supported by virtual zones.
For more details on how to enable Stay attribute for zone, please refer to 14.6. Zone Attributes.