MANUAL ELDES ESIM364 V1.3 41
1. In order to instantly turn ON a specied PGM output and keep it in this state for a determined time period, send
the following SMS text message to the system’s phone number from any out of 10 preset user phone numbers:
SMS text message content:
ssss_Coo:ON:hr.mn.sc or ssss_out-name:ON:hr.mn.sc
Value: oo – PGM output number, range – [1... 76]; hr – hours, range – [00... 23], mn – minutes, range – [00... 59];
sc – seconds, range – [00... 59]; out-name – PGM output name.
Example: 1111_Pump:ON:00.00.25
2. In order to instantly turn OFF a specied PGM output and keep it in this state for a determined time period,
send the following SMS text message to the system’s phone number from any out of 10 preset user phone
numbers:
SMS text message content:
ssss_Coo:OFF:hr.mn.sc or ssss_out-name:OFF:hr.mn.sc
Value: oo – PGM output number, range – [1... 76]; hr – hours, range – [00... 23], mn – minutes, range – [00... 59];
sc – seconds, range – [00... 59]; out-name – PGM output name.
Example: 1111_C3:OFF:13.25.56
3. The system will reply with conrmation by SMS text message to the user phone number that sent the SMS text
message.
SMS
Fig. No. 36
User
ESIM364
SMS
SMS
3.12 Turning ON/OFF the Electrical Appliances for a Determined Time Period
NOTE: PGM output can be turned ON for a determined time period only when it is in OFF state.
NOTE: PGM output can be turned OFF for a determined time period only when it is in ON state.