14. ZONES
Detection devices such as motion detectors and door contacts are connected to the alarm system’s zone terminals. Once connected, the
associated zone’s parameters must be congured.
ESIM364 comes equipped with 6 on-board zones allowing to connect up to 6 detection devices. For more details regarding zone expansion,
please refer to 14.2. Zone Expansion.
ESIM364 zones are classied by 5 categories:
Zone category Description
Max. number of
zones per device
Max. number of
zones in total
On-board Zones Built-in wired zones of ESIM364 alarm system. 6/12* 6/12*
Keypad zones Hardwired zones of EKB2/EKB3 keypad. 1 4
EPGM1 zones Zones of EPGM1 - hardwired zone & PGM output expansion
module.
16 32
Wireless zones Non-physical zones automatically created by connected
wireless devices.
2** 64***
Virtual zones
Non-physical zones intended for Panic button feature (alarm
activaiton upon pressing the button) on EWK1 wire less key-
fob. Virtual zones can be manually created using ELDES Con-
guration Tool software.
64**** 64****
* - 6-Zone mode is enabled by default. ATZ mode doubles the on-board zone number and increases it to 12 in total.
** - Depends on the connected wireless device.
*** - Available only if no zones, EPGM1 zones and virtual zones are present.
**** - Available only if no zones, EPGM1 zones and wireless zones are present.
14.1. Zone Numbering
The zone numbers ranging from Z1 through Z12 are permanently reserved for on-board zones even when ATZ mode is disabled. The
Z13-Z76 zone numbers are automatically assigned in the chronological order to the created virtual zones and the devices connected to the
system: keypads, wireless devices, EPGM1 modules.
14.2. Zone Expansion
For additional detection device connection, the number of zones can be expanded by:
• enabling the ATZ (Advanced Technology zone) mode (see 14.4. ATZ (Advanced Technology Zone) Mode).
• connecting EPGM1 hardwired zone and PGM output expansion module (see 32.1.3. EPGM1 – Hardwired Zone & PGM Output Ex-
pansion Module).
• connecting keypads (see 32.1.1. EKB2 – LCD Keypad, 32.1.2. EKB3 – LED Keypad and 33.1. EKB3W – Wireless LED Keypad).
• binding wireless devices (see 19. WIRELESS DEVICES).
• creating virtual zones (see ELDES Conguration Tool software’s Help section).
The maximum supported number of zones is 76.
14.3. 6-Zone Mode
By default, ESIM364 alarm system runs in the 6-Zone mode under zone connection Type 1 allowing to connect up to 6 detection devices
of NO (normally-open) type to the on-board zone terminals as indicated in the wiring diagram of Type 1. Once a dierent zone connection
type is set, the detection device wiring must be done according to the wiring diagram of the associated type. Available zone connection
types for the 6-Zone mode:
• Type 1 – Parallel wiring of NO (normally-open) detection device with 5,6k EOL (end-of-line) resistor.
• Type 2 – Serial wiring of NC (normally-closed) detection device with 5,6k EOL resistor.
• Type 3 – Combination of serial and parallel wiring of tamper with 5,6k EOL resistor and NC (normally-closed) detection device with
3,3k EOL resistor.
For zone wiring diagrams of the 6-Zone mode, please refer to 2.3.2. Zone Connection Types.
Set zone connection
type for 6-Zone mode
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK ZONES OK ZONE TYPE:6-ZONE M
OK TYPE 1... 3 OK
Value: aaaa – 4-digit administrator password.